Прямоточный парогенератор

Дипломная работа - Физика

Другие дипломы по предмету Физика

9

0.001345 1.89 91.82 245467 574.2 0.85 0.83 21.752

0.001355 1.91 90.71 248467 569.0 0.85 0.83 21.812

0.001371 1.93 89.05 253092 560.7 0.87 0.84 21.897

0.001387 1.95 87.42 257819 552.1 0.88 0.85 21.990

0.001404 1.98 85.81 262663 543.1 0.90 0.85 22.092

0.001422 2.00 84.21 267641 533.7 0.92 0.86 22.205

0.001436 2.02 83.10 271225 526.9 0.93 0.90 22.071

0.001443 2.03 82.48 273256 523.1 0.94 0.91 22.115

0.001451 2.04 81.86 275312 519.1 0.95 0.91 22.161

0.001459 2.05 81.25 277396 515.1 0.96 0.92 22.211

0.001467 2.07 80.64 279508 511.1 0.97 0.92 22.263

0.001472 2.07 80.27 280782 508.7 0.98 0.93 22.299

0.001473 2.08 80.16 281178 507.9 0.98 0.93 22.282

0.001475 2.08 80.04 281574 507.2 0.99 0.94 22.264

0.001476 2.08 79.93 281972 506.4 0.99 0.95 22.246

0.001478 2.08 79.82 282371 505.6 0.99 0.95 22.227

0.001480 2.08 79.71 282771 504.9 0.99 0.96 22.208

0.001481 2.09 79.59 283171 504.1 1.00 0.96 22.187

0.001483 2.09 79.48 283573 503.3 1.00 0.97 22.165

0.001484 2.09 79.37 283977 502.6 1.00 0.98 22.143

0.001486 2.09 79.26 284364 501.8 1.00 0.99 22.118

параметры 2 контура

уд. объем скорость дин. вязк. Re теплопров. Pr Pr-стенки коэф. теплоотдачи x

 

куб.м/кг м/с мкПа*с мВт/(м*К) кВт/(кв.м*К)

 

0.001021 0.76 404.39 22761 663.5 2.55 1.04 6.842

0.001034 0.77 315.10 29211 675.7 1.96 1.00 7.249

0.001050 0.78 255.40 36039 682.2 1.58 0.95 7.618

0.001068 0.79 213.53 43105 684.3 1.33 0.92 7.953

0.001088 0.81 183.11 50266 682.8 1.15 0.89 8.256

0.001111 0.82 160.38 57392 678.0 1.03 0.86 8.532

0.001137 0.84 142.94 64393 670.2 0.94 0.84 8.783

0.001166 0.87 129.22 71232 659.3 0.89 0.83 9.014

0.001199 0.89 118.11 77933 645.1 0.85 0.83 9.232

0.001240 0.92 108.11 85136 625.6 0.83 1.30 8.477 0.000

0.001263 0.94 103.72 88742 614.2 0.83 1.31 24.282 0.138

0.001263 0.94 103.73 88734 614.2 0.83 1.31 26.228 0.282

0.001263 0.94 103.74 88727 614.2 0.83 1.31 28.115 0.427

0.001263 0.94 103.75 88721 614.2 0.83 1.30 29.944 0.572

0.001263 0.94 103.75 88715 614.3 0.83 1.30 31.715 0.717

0.046513 34.53 17.76 518379 51.7 1.42 1.15 3.000 0.774

0.046946 34.85 17.74 518983 51.5 1.42 1.14 3.209 0.830

0.047355 35.15 17.72 519549 51.4 1.41 1.14 3.417 0.887

0.047743 35.44 17.70 520080 51.3 1.41 1.14 3.622 0.943

0.048113 35.71 17.68 520583 51.2 1.41 1.14 3.827 1.000

0.048776 36.21 17.77 517845 51.0 1.37 1.13 4.193

0.049763 36.94 17.99 511704 50.7 1.31 1.13 4.027

0.050799 37.71 18.22 505246 50.5 1.27 1.12 3.888

0.051858 38.49 18.46 498701 50.4 1.23 1.11 3.772

0.052941 39.30 18.70 492110 50.3 1.20 1.11 3.674

0.054052 40.12 18.96 485506 50.3 1.18 1.10 3.589

0.055197 40.97 19.22 478916 50.4 1.16 1.10 3.515

0.056387 41.86 19.49 472365 50.5 1.14 1.09 3.450

0.057640 42.79 19.76 465876 50.6 1.12 1.09 3.391

0.058994 43.79 20.03 459476 50.8 1.11 1.08 3.339

общие параметры

ср.темп.1к. темп. трубы(нар) темп. трубы(вн) ср.темп.2к. темп. напор

 

град.С град.С град.С град.С град.С

 

275.8 245.1 166.7 70.2 205.6

277.3 248.5 175.9 90.3 187.0

278.8 252.2 185.8 110.3 168.5

280.3 256.1 196.2 130.2 150.1

281.8 260.1 207.0 149.9 131.9

283.3 264.2 218.1 169.4 113.9

284.8 268.3 229.3 188.6 96.2

286.3 272.6 240.5 207.4 78.9

287.7 276.8 251.6 225.8 61.9

288.6 281.7 264.6 244.6 44.0

292.0 283.1 262.7 254.6 37.4

296.2 286.1 263.0 254.6 41.6

300.3 289.1 263.4 254.6 45.7

304.3 292.0 263.7 254.6 49.7

308.2 294.8 264.0 254.6 53.6

310.9 305.5 293.7 254.3 56.6

312.4 306.6 293.7 253.7 58.6

313.8 307.6 293.8 253.2 60.6

315.3 308.6 293.8 252.8 62.5

316.7 309.6 293.8 252.3 64.4

317.6 310.2 293.7 254.2 63.4

317.8 311.1 296.1 258.6 59.2

318.1 312.0 298.5 263.4 54.7

318.4 312.9 300.8 268.4 49.9

318.6 313.7 303.1 273.6 45.0

318.9 314.6 305.3 279.0 39.8

319.1 315.5 307.6 284.6 34.5

319.4 316.4 309.8 290.3 29.0

319.6 317.2 312.0 296.2 23.4

319.9 318.1 314.2 302.2 17.7

терм. сопр., м*К/кВт теплопров. мет. коэф. теплопер. длина

 

к. 2к. мет. мВт/(м*К) кВт/(м*К) кВт/(кв.м*К) м

 

2.90 11.79 8.40 0.015 0.0433 3.213 0.2696

2.90 11.12 8.29 0.015 0.0448 3.317 0.2865

2.89 10.59 8.19 0.016 0.0462 3.411 0.3086

2.89 10.14 8.07 0.016 0.0474 3.497 0.3374

2.88 9.77 7.96 0.016 0.0485 3.575 0.3750

2.88 9.45 7.85 0.016 0.0496 3.648 0.4251

2.88 9.18 7.74 0.016 0.0505 3.715 0.4938

2.87 8.95 7.63 0.017 0.0514 3.778 0.5920

2.87 8.74 7.53 0.017 0.0523 3.837 0.7419

2.87 9.51 7.41 0.017 0.0505 3.723 1.0809

2.87 3.32 7.42 0.017 0.0735 5.214 2.5442

2.85 3.07 7.39 0.017 0.0751 5.313 2.2404

2.84 2.87 7.37 0.017 0.0764 5.400 2.0019

2.83 2.69 7.35 0.017 0.0777 5.479 1.8104

2.81 2.54 7.33 0.017 0.0788 5.551 1.6534

2.83 26.88 7.08 0.018 0.0272 2.089 1.7757

2.83 25.13 7.08 0.018 0.0285 2.189 1.6324

2.82 23.60 7.07 0.018 0.0299 2.285 1.5100

2.81 22.26 7.07 0.018 0.0311 2.376 1.4045

2.81 21.08 7.06 0.018 0.0323 2.463 1.3126

2.80 19.23 7.06 0.018 0.0344 2.611 0.2310

2.80 20.03 7.04 0.018 0.0335 2.547 0.2537

2.81 20.74 7.02 0.018 0.0327 2.492 0.2812

2.81 21.38 7.00 0.018 0.0321 2.445 0.3142

2.81 21.95 6.98 0.018 0.0315 2.405 0.3551

2.81 22.47 6.96 0.018 0.0310 2.370 0.4073

2.82 22.94 6.95 0.018 0.0306 2.338 0.4768

2.82 23.38 6.93 0.018 0.0302 2.310 0.5740

2.82 23.78 6.91 0.018 0.0298 2.285 0.7196

2.83 24.15 6.90 0.018 0.0295 2.262 0.9624

разбивка труб по змеевикам

5

6

7

7

8

9

10

10

11

12

13

13

14

15

16

16

17

18

19

Приложение Б

 

Результаты расчета долевых режимов

 

расчет долевых режимов

при нагрузке 70 %

исходные данные

материал труб: титановый сплав

количество змеевиков 19

количество параллельных труб 215.0

давление в первом контуре 13.00 МПа

температура теплоносителя на входе в ПГ 313.3 град.С

температура теплоносителя на выходе из ПГ 281.8 град.С

кпд парогенератора 0.993

мощность ПГ 34.875 МВт

давление пара на выходе из ПГ 4.00 МПа

температура питательной воды 90.0 град.С

температура перегретого пара на выходе из ПГ 312.6 град.С

гидравлическое сопротивление змеевиков по первому контуру 0.050 МПа

гидравлическое сопротивление змеевиков по второму контуру 0.300 МПа

обечайка, на которую навивается первый змеевик 200.0 мм

наружный диаметр труб 16.0 мм

толщина стенки труб 1.8 мм

поперечный шаг 20.4 мм

результаты расчета

интегральные параметры

высота трубной системы 2.674 м

наружный диаметр трубной системы 0.983 м

гидравлическое сопротивление змеевиков по первому контуру 0.0504 МПа

гидравлическое сопротивление змеевиков по второму контуру 0.2002 МПа

количество параллельных труб 215.20

поперечный шаг 20.39 мм

расход по первому контуру 202.09 кг/с

длина трубы 27.539 м

поверхность теплообмена 248.832 м

паропроизводительность 13.24 кг/с

мощность экономайзера 9.516 МВт

мощность испарителя 22.512 МВт

в том числе

мощность участка без кризиса 19.470 МВт

мощность участка с кризисом второго рода 3.042 МВт

мощность пароперегревателя 2.603 МВт

экономайзер испаритель испаритель пароперегреватель

без кризиса с кризисом

коэф. теплоотдачи по 1 контуру, кВт/(кв.м*К) 21.45 21.66 21.72 21.64

коэф. теплоотдачи по 2 контуру, кВт/(кв.м*К) 6.27 27.03 2.73 2.51

коэффициент теплопередачи, кВт/(кв.м*К) 3.19 5.33 1.95 1.84

длина т?/p>